The IOTA ETS-DR Emergency Lighting Control Device allows local switch and/or 0-10V dimming control of designated emergency luminaires when emergency power is provided by a generator or inverter. The ETS-DR senses the loss of normal AC power and bypasses the local switch device allowing emergency power directly to the fixture regardless of switch position.
Product Advantages
  • Regain local switch control of your designated emergency fixtures powered from a generator or inverter
  • Promotes Energy Savings by eliminating the need for always-on fixtures
  • Full Light Output
  • Compatible with LED loads up to 3amps continuous in accordance with NEMA 410
  • Dimming Relay Leads accommodate 0-10V dimming controls
Features
  • Shuts local switch devices in emergency mode allowing for full lumen output
  • Galvanized steel case
  • Available in flex or non-flex configuration
  • Rated for use in plenum fixtures
  • Meets or exceeds all NEC, IBC, and Life Safety Code Emergency Lighting Requirements
  • RoHS Compliant
Read More
Read Less
Product Type Emergency Control Device
Voltage Rating 120-277
Frequency 60HZ
Max. Controlled Current 3A
Max. Input Current 40mA
Max. Operating Temp. 65
Min. Operating Temp. -20
Life Safety Testing Manual Testing
Regulatory Listing cUL
Compliance Listing ROHS
Series ETS

Read More Read Less

  • Suggested Replacement Products

PRODUCT INFORMATION

  • Spec Sheets

    Document Type Document Title Description Updated View
    SPEC SHEET ETS_DR_seriesHi-Temp.pdf ETS DR Specification Sheet 5/12/2020 View
  • Photometry & Revit (BIM)

  • Spectral Data Sheets

  • Guideline Specifications

  • Revit Component Files (Non-Illuminated)

  • Technical Documents (e.g. Instruction Sheets, MSDS, CAD)

    Document Type Document Title Description Updated View
    Installation Instructions ETS-DR Series Hi-Temp_Manual.pdf ETS DR Series Hi-temp Installation Manual 5/12/2020 View
    Technical Bulletins ETS DR NOKIT Technical Bulletin Describes the ETS DR NOKIT model option of the ETS DR 6/23/2021 View
    Wiring Diagram Separately Derived System (Switched Neutral) PDF File - Typical generator application in conjunction with a double-pole 1008 transfer switch 7/16/2020 View
    Wiring Diagram Separately Derived System (Switched Neutral) DWG File - Typical generator application in conjunction with a double-pole 1008 transfer switch 7/16/2020
    Wiring Diagram Typical Application DWG File - Typical generator application with a 0-10V dimming control 7/16/2020
    Wiring Diagram Typical Application PDF File - Typical generator application with a 0-10V dimming control 7/16/2020 View
  • Utility Rebate Search

  • Replacement Parts

  • Confidential Documents

  • Marketing Material (e.g. Brochures, Sell Sheets, FAQs, )

    Document Type Document Title Description Updated View
    Application Guide ETS DR Product Spotlight A brief (2-page) overview of the advantages of including the IOTA ETS DR in your emergency circuit 3/9/2021 View
    Application Guide IOTA Contractor Insider_ALCR and dimming.pdf Learn how Dimming Relay leads save time and money when using ALCRs in 0-10V dimming applications. 7/13/2021 View
    Application Guide The ETS DR with Micro-Inverters and 0-10V Dimming Use the dimming relay leads of the ETS DR to include 0-10V dimming with IOTA micro-inverters. 4/12/2022 View
    Brochures IOTA HE Products for California Title 20 IOTA Emergency Lighting Solutions Certified in the Title 20 Appliance Efficiency Database 7/21/2022 View
  • Need Product Assistance? (e.g. How to Buy, Technical Support, Warranty)

    How to Buy

    The IOTA products are primarily sold through a network of agents and distributors across North America.

    •  Find an Agent or Distributor

    •  Request a Call


    Technical Support

    The IOTA technical team is dedicated to providing outstanding product support. Please click on the appropriate link below,
    or feel free to call us at 855.363.9527.

    •  FAQs

    •  Technical Library

    •  Email Us


    Warranty

    Please click on the appropriate link below to learn more about IOTA terms & conditions and product warranty options. 

    •  IOTA Emergency Products with Batteries

    •  IOTA Emergency Control (ALCR) Devices

    •  IOTA DLS Battery Chargers and Power Converters

    •  IOTA Warranty Replacements & Stock Returns


Stocked

View Stocked Products

  • Stock-Sku-FeedbackIs the new stocked product detail helpful? Please tell us what you think, CLICK HERE.

    SKU data not available, please contact your local agent.

    {{getMinimumDisplayedIndex()}} - {{getMaximumDisplayedIndex()}} of {{filteredStockedProducts.length}} results

    {{icon.AltText}}
    Close Details View
    Product Details
    exclamation-v2-YL
    Product information is not available at this time. Please try again later.
    (No Products Found)
    {{icon.AltText}}
    {{result.Title}}
    {{result.Title}}
    {{result.Description}}
    Quantity
    {{(result.Quantity > 0) ? result.Quantity : 0}} in {{result.Location.substring(result.Location.indexOf("(")+1, result.Location.indexOf(")"))}}
    Total at all DCs: {{result.EnterpriseAvailability}}
    Distr. Price
    ${{result.Price | number : 2}}
    Distr. Price
    Contact Acuity
    Distr. Price
    Contact Rep
    Distr. Price
    GET PRICE
    Distr. Price
    No pricing established

    No Locations Could Be Found.


    This catalog # is not available at any location at this time. Inventory is replenished daily, please check back or contact your local sales representative or agency further details.

    exclamation-v2-YL
    Your session has expired. Click on the login link to view stocked product information.
    Login/Register
    exclamation-v2-YL
    Product information is not available at this time. Please try again later.
    Important Notice Orders entered before noon will ship same day, and orders entered after noon will ship next day within your given timezone.
    Available Est. Ship Date Location In Transit
    {{loc.QUANTITY > 0 ? loc.QUANTITY : 0}} {{loc.ESTIMATED_SHIP_DATE}} {{loc.LOCATION}}     {{loc.IN_TRANSIT_QUANTITY}}
    Restocking date is unavailable at this time.
    Location Est. Restocking Qty & Date
    {{transitDetail.QUANTITY > 0 ? transitDetail.QUANTITY : 0}}{{transitDetail.ARRIVAL_DATE ? transitDetail.ARRIVAL_DATE : "Date Not Provided"}}
    Available
    {{loc.QUANTITY > 0 ? loc.QUANTITY : 0}}
    Est. Ship Date
    {{loc.ESTIMATED_SHIP_DATE}}
    Location
    {{loc.LOCATION}}
    In Transit
    {{loc.IN_TRANSIT_QUANTITY}}
    Restocking date is unavailable at this time.
    Location Est. Restocking Qty & Date
    {{transitDetail.QUANTITY > 0 ? transitDetail.QUANTITY : 0}}
    {{transitDetail.ARRIVAL_DATE ? transitDetail.ARRIVAL_DATE : "Date Not Provided"}}
Configurator

Build Cat. # / Submittal Spec Sheet

  • Start Configurating a Product

Videos

Compatible Products

  • Fixtures
Other People Have Also Viewed