IIS 375 I Emergency Inverter
By IOTA
- Overview
- Specifications
Load Capability
- 375 Watts
Compatible Load Types
- Fluorescent
- Incandescent
Features
- Emergency lighting supplied from one convenient source
- Pure sine wave output
- Operates fixtures with dimmable ballasts and screw-base lamp types
- Includes momentary contact test switch, yellow ready indicator, green inverter-on indicator, and red charging indicator
- Variable-rate, temperature compensated charger
- Valve Regulated Lead Acid (VRLA) battery provides long life and is maintenance free
- Line voltage allows for remote mounting of emergency fixtures at distances up to 1000 feet
- Resettable output circuit breaker provides protection against circuit overload
- Low Battery Voltage Disconnect and Line Latch Protection
- Allows for emergency operation of switched and unswitched fixtures
- Meets or exceeds all NEC, IBC, and Life Safety Code Emergency Lighting Requirements
- Durable 16-gauge steel housing design with white semi-gloss powerder-coat paint finish
Product Type | Emergency Inverter |
Voltage Rating | 120/277 |
Frequency | 60HZ |
Load Voltage Rating | 120VAC, 277VAC |
Output Power | 375 Watts |
Max. Operating Temp. | 30 |
Min. Operating Temp. | 20 |
Battery Run Time | 90 min |
Battery Chemistry Type | Lead Acid |
Life Safety Testing | Manual Testing |
Regulatory Listing | UL |
Compliance Listing | ROHS |
Series | IIS |
Read More Read Less
-
Suggested Replacement Products
PRODUCT INFORMATION
-
Spec Sheets
Document Type Document Title Description Updated View SPEC SHEET IIS 375 I Specifications Specification Sheet for IIS 375 I Models 3/23/2022 View -
Photometry & Revit (BIM)
-
Spectral Data Sheets
-
Guideline Specifications
-
Revit Component Files (Non-Illuminated)
Document Type Document Title Description Updated View BIM Models IIS 375 I.rfa IIS 375 I 12/16/2021 View -
Technical Documents (e.g. Instruction Sheets, MSDS, CAD)
Document Type Document Title Description Updated View Installation Instructions IIS 375 I DR Manual IIS 375 I DR (Dimming Relay) Model 2/22/2021 View Installation Instructions IIS 375 I Manual IIS 375 I (Standard) Model 2/22/2021 View Material Safety Data Sheet MSDS-HY_Sealed-Lead-Acid-Battery.pdf Safety Data Sheet for Sealed Lead Acid Battery component 5/13/2021 View Technical Bulletins IOTA Contractor Insider_Extending-Runtimes.pdf IOTA offers different ways to achieve extended runtimes for 120-minute emergency applications 7/23/2021 View Wiring Diagram (DWG) Dimming Relay (DR) Model DWG Format - Connections to an emergency load with a 0-10V dimming control 7/9/2020 View Wiring Diagram (DWG) Dimming Relay (DR) Models - Without Circuit Breaker DWG Format - Connections to an emergency load with a 0-10V dimming control (legacy models - no internal circuit breaker) 7/9/2020 View Wiring Diagram (DWG) Typical Installation DWG Format - Connections to an emergency load with an optional switched input 7/9/2020 View Wiring Diagram (DWG) Typical Installation - Without Circuit Breaker DWG Format - Connections to an emergency load with an optional switched input (legacy models - no internal circuit breaker) 7/9/2020 View Wiring Diagram (PDF) Dimming Relay (DR) Model PDF Format - Connections to an emergency load with a 0-10V dimming control 7/9/2020 View Wiring Diagram (PDF) Dimming Relay (DR) Model - Without Circuit Breaker PDF Format - Connections to an emergency load with a 0-10V dimming control (legacy models - no internal circuit breaker) 7/9/2020 View Wiring Diagram (PDF) Typical Installation PDF Format - Connections to an emergency load with an optional switched input 7/9/2020 View Wiring Diagram (PDF) Typical Installation - Without Circuit Breaker PDF Format - Connections to an emergency load with an optional switched input (legacy models - no internal circuit breaker) 7/9/2020 View -
Utility Rebate Search
-
Replacement Parts
-
Confidential Documents
-
Marketing Material (e.g. Brochures, Sell Sheets, FAQs, )
Document Type Document Title Description Updated View Application Guide Contractor Insider - Remote Mounting Guidelines A Quick Reference for knowing remote mounting capabilities of emergency lighting solutions. 10/21/2021 View Application Guide IIS Mini and Micro Inverter Remote Mounting Guidelines for remote mounting IOTA IIS mini and micro-inverter systems 1/4/2023 View Application Guide Tech App_Mini-Inverters and Outdoor Egress.pdf Understand How IIS Mini Inverters Solve Unique Outdoor Emergency Lighting Challenges 7/23/2021 View -
Need Product Assistance? (e.g. How to Buy, Technical Support, Warranty)
How to Buy
The IOTA products are primarily sold through a network of agents and distributors across North America.
• Find an Agent or Distributor
Technical Support
The IOTA technical team is dedicated to providing outstanding product support. Please click on the appropriate link below,
or feel free to call us at 855.363.9527.• FAQs
• Email Us
Warranty
Please click on the appropriate link below to learn more about IOTA terms & conditions and product warranty options.
• IOTA Emergency Products with Batteries
• IOTA Emergency Control (ALCR) Devices
• IOTA DLS Battery Chargers and Power Converters
• IOTA Warranty Replacements & Stock Returns

View Stocked Products
-
Is the new stocked product detail helpful? Please tell us what you think, CLICK HERE.
SKU data not available, please contact your local agent.
{{getMinimumDisplayedIndex()}} - {{getMaximumDisplayedIndex()}} of {{filteredStockedProducts.length}} results
(No Products Found){{result.Title}}{{result.Title}}{{result.Description}}Quantity{{(result.Quantity > 0) ? result.Quantity : 0}} in {{result.Location.substring(result.Location.indexOf("(")+1, result.Location.indexOf(")"))}}Total at all DCs: {{result.EnterpriseAvailability}}Distr. Price${{result.Price | number : 2}}Distr. PriceContact AcuityDistr. PriceContact RepDistr. PriceGET PRICEDistr. PriceNo pricing establishedNo Locations Could Be Found.
This catalog # is not available at any location at this time. Inventory is replenished daily, please check back or contact your local sales representative or agency further details.
Your session has expired. Click on the login link to view stocked product information.
Login/RegisterProduct information is not available at this time. Please try again later.Available Est. Ship Date Location In Transit {{loc.QUANTITY > 0 ? loc.QUANTITY : 0}} {{loc.ESTIMATED_SHIP_DATE}} {{loc.LOCATION}} {{loc.IN_TRANSIT_QUANTITY}} Restocking date is unavailable at this time. Location Est. Restocking Qty & Date {{transitDetail.QUANTITY > 0 ? transitDetail.QUANTITY : 0}}{{transitDetail.ARRIVAL_DATE ? transitDetail.ARRIVAL_DATE : "Date Not Provided"}} Available{{loc.QUANTITY > 0 ? loc.QUANTITY : 0}}Est. Ship Date{{loc.ESTIMATED_SHIP_DATE}}Location{{loc.LOCATION}}In Transit{{loc.IN_TRANSIT_QUANTITY}}Restocking date is unavailable at this time.Location Est. Restocking Qty & Date{{transitDetail.QUANTITY > 0 ? transitDetail.QUANTITY : 0}}{{transitDetail.ARRIVAL_DATE ? transitDetail.ARRIVAL_DATE : "Date Not Provided"}}View AllView Less

Build Cat. # / Submittal Spec Sheet
-
Start Configurating a Product
Compatible Products
- Accessories