Version 201.22.03/2019 - RELEASE NOTES
New Features 

  • Enabled support for nLight firmware release (final) 

  • BACnet client diagnostics in system diagnostics tab 
Bugs Fixed 
  • Fixed scheduling scripts to stop from Fresco Studio failed 

  • Fixed DMX color temperature limits require manual sync after power up 

  • Fixed missing nPODM-4S-DX in nLight library known Issues 

  • Mobile app does not support scene toggle 


Fresco Studio 2.3.1 Release Notes


New Features 

  • nLight library updated for the latest global firmware release. 

  • New text search to filter Hardware, Inputs and Outputs views. 

  • Hardware tree dynamically sorts when updating controller IDs. 

  • New scheduling option to display past special assignments. 

  • Update tool inherits FCN port number from Studio preferences when launched from Studio. 

  • New splash screen design for both Studio and Update Tool. 

Fixes and Enhancements 
  • Script editing improved for drag/drop and copy/paste actions. 

  • Fix for executing a scheduled stop script after export. 

  • Show only valid selections for controllers with scripts for all views. 

  • Full 4-part version numbers displayed for new Studio releases. 

  • Calendar scheduling action buttons now update based on the date selected. 

  • Other general stability and performance improvements. 


VERSION 201.19 02/2019 - RELEASE NOTES 

New Features

  • Added BACnet Client functionality.

  • Provides on-screen method to link to profiles on nECY allowing a single scheduling interface.

  • Updated nLight library includes additional nCM devices.

  • Bugs Fixed

  • Fixed time drift on some Fresco Touchscreens.

  • Fixed one time scheduled events that failed to load.
Known Issues
  • DMX color temperature limits require manual sync after power up.

  • Mobile app does not support scene toggle.

Fresco Studio 2.3.0 Release Notes


New BACnet/IP Client Feature

  • Manage up to 100 BACnet Client devices for each master controller in the hardware tree.

  • Configure BACnet/IP read remote properties with option to subscribe to COV.

  • Configure BACnet/IP write remote properties.

  • Set IP address for the Default Gateway when configuring BBMD networking.

  • Automatic upgrade existing studio projects to support new BACnet features.
Fixes and Enhancements
  • Prevent multiple instances of Update window from opening.

  • Allow single click to select check boxes for Room Links, Channels, and Scenes.

  • Manual ID changes are applied correctly across multiple controllers, scripts, and BACnet mappings.

  • Fixed Room Link dialog distortion on higher HD display resolutions.

  • Script 'Set' command no longer requires selecting the script ID twice.

  • Cancel button on Project Save dialog will cancel instead of exiting Studio.

  • Updated nLight library includes additional nCM devices.


VERSION 200.50 12/2018 - RELEASE NOTES
New Features
  • Added support for new Winline 501 DMX fixtures
Bugs Fixed
  • Fixed color temperature fade for DMX outputs

  • Fixed lighting state restore when multiple devices have outputs in the same zone

  • Fixed issue where updating firmware on RBs and AVIs failed
Known Issues
  • DMX color temperature limits require manual sync after power up

  • Mobile app does not support scene toggle


VERSION 200.42 8/2018 – RELEASE NOTES
New Features
  • Unmasking an occupancy sensor updates the output if the sensor became vacant while masked

  • Added a System Diagnostics tab which displays available memory
Bugs Fixed
  • Color temperature limits failed to sync across multiple Frescos

  • nLight "Add all" button cleared zone assignments

  • Input masking/unmasking through a script did not work across networks

  • Some Frescos would fail to connect via Ethernet
Known Issues
  • Mobile app does not support scene toggle


VERSION 200.38 4/2018 – RELEASE NOTES

Bugs Fixed
  • Uncontrolled reset when controlling large systems

  • Channel control zone selector only shows first 255 zones

  • DMX flicker when performing FCN operations

  • Scene button activation state incorrect after unlinking

  • Room link state lost after a restart on a non-master Fresco
Known Issues
  • Mobile app does not support scene toggle


VERSION 200.36 3/2018 – RELEASE NOTES

New Features
  • Lighting levels preserved after reset or power failure

  • 72 Channels in each Fresco room

  • nLight ARP setup experience improved (including Fresco Studio support)

  • Scene save protection to prevent invalid scenes

  • Scenes are now able to toggle on/off

  • New nLight devices highlighted when connected

  • Offline nLight devices shown with red text

  • Fresco now displays nLight global channel utilization on diagnostics screen

  • nLight firmware version added to setup tree

  • Improved Ethernet firmware update speed

  • Searchable DMX Device List

  • Uptime status of Fresco devices on diagnostics screen and in Fresco Studio

  • FCN devices requiring firmware updates shown with red text

  • Scripting – Adds ability to setup conditional logic and loops
Bugs Fixed
  • FCN protocol rewritten for greater reliability

  • General UI improvements for readability and consistency

  • DMX color temperature fixture 1440 does not appear to turn on

  • nTune fixture flashes and goes full bright

  • Mobile app unable to control Fresco

  • nPP16 D “V3” bug

  • nPODM 4S DX EDUTW bug

  • BACnet COV only supports subscription from one BACnet Client

  • And much much more
Known Issues
  • nIO 1S will lose programming during update to v200

  • Mobile app does not support scene toggle


VERSION 111.34 10/2017 – RELEASE NOTES

Bugs Fixed 
  • nLight tunable white fixture forgets color temperature during off to on cycle


VERSION 111.33 10/2017 – RELEASE NOTES

Bugs Fixed
  • Dual Zone photocell patch

  • nLight devices following photocell stop responding to updates


VERSION 111.31 10/2017 – RELEASE NOTES

New Features
  • Zone level control of a daylight harvesting group

  • Improved multi-zone daylight harvesting control
Bugs Fixed
  • Photocell controlled dimmers do not turn on

  • ARP outputs do not dim


VERSION 111.25 – 2/2017 RELEASE NOTES

New Features
  • Initial nLight® Relay Panel support
Bugs Fixed
  • Photocell dim-to-off does not shut relay off

  • Bluetooth® hangs up shortly after connecting

  • DMX color temperature fixture not being controlled


VERSION 111.20 – 12/2016 RELEASE NOTES

New Features
  • nLight® nTune support

  • On-screen Room Link Control

  • Live configuration of nLight devices without restarting

  • Support Somfy® Shades
Bugs Fixed
  • Linked room scene activation causes AVI timeout error


VERSION 110.07 - 9/2016 RELEASE NOTES

New Features
  • BACnet™ Mapping Editor

  • Add support for Indy™ ChromaControl™ and Aculux™ DMX luminaires


VERSION 109.16 - 8/2016 RELEASE NOTES

New Features
  • Daylighting for any zone – Supports DMX luminaires and LMP

  • Zone Editor 

  • Fresco stations stop being discovered 

  • Custom logo causes restart 
Bugs Fixed
  • Input lower operations will lower the lights to off


VERSION 108.39 - 6/2016 RELEASE NOTES

New Features
  • Support control by room

  • nLight automatic set point calibration

  • nLight Microphonics support

  • Bluetooth® lockup during full-duplex communications

  • Groups are automatically assigned to all channels when selecting a multi-lettered room

  • Timeouts not functioning with multiple Fresco units

  • nRM does not appear functional with Fresco
Bugs Fixed
  • Bluetooth® lockup during full-duplex communications

  • Groups are automatically assigned to all channels when selecting a multi-lettered room

  • Timeouts not functioning with multiple Fresco units

  • nRM does not appear functional with Fresco

  • Occupancy sensor does not time out or lights turn off


VERSION 107.36 - 3/2016 RELEASE NOTES


New Feature
  • Support 72 channels

  • Complete scheduling user-interface

  • Bootloader and application validation

  • Synchronization of global data

  • Property transfer
Bugs Fixed
  • Exiting attribute page on another page returns to first page

  • Input assigned to control a zone on another station doesn't get controlled

  • AV interface scene activation does not trigger correct scene

  • AV interface scene status and channel status timeout

  • Upon linked Fresco restarting, channels go to indeterminate state

  • Channel levels do not always update successfully in linked room

  • ColorTemp not working on channels greater than 6

  • Configured nLight ADC not dimming its load

  • Fresco units on local network not discovered via Ethernet

  • nLight occupancy timeout is invalid


VERSION 106.22 – 12/2015 RELEASE NOTES

New Feature: 
  • Identify + Blink Warning


VERSION 105.16 – 7/2015 RELEASE NOTES

New Feature: 
  • Lutron® QSE Shade Support


VERSION 104.03 – 3/2015 RELEASE NOTES

New feature:
  • Photocell Device Support


VERSION 103.18 – 10/2014 RELEASE NOTES

New Feature
  • nLight Device Library
Known Issue
  • Must be updated to version 104.03 before later updates can be applied


VERSION 103.06 – 7/2014 RELEASE NOTES

New Feature:
  • Initial Release
 Known Issue:
  • Must be updated to version 104.03 before later updates can be applied